SHV Connectors are available for a variety of coaxial cable types including RG58, and RG59. However, you do need to be aware that these cable types themselves are typically rated at  2kV peak voltage, or less, ( it can vary according to source) and that any cable assembly is only as good as its weakest component.

TYPICAL COAXIAL CABLE DATA                
Type Nom. Imp Zo Outer Dia. (mm) Nom loss (dB/100m) @ 50 MHz Attenuation (dB/100m) Vel. Factor % Cap. pF/m Voltage Rating {Vrms}
100 MHz 200 MHz 400 MHz 1GHz
RG – 6A/U 75 7 4.73 6.37 8.89 13.1 ~26 82 53.1 2700
RG – 8/U 52 10.3 5.2 7.2 10.5 15.4 29.2 66 96.8 5000
RG – 9/U 51 10.67 5.2 7.2 10.5 15.4 29.2 66 98.4 5000
RG – 11/U 75 10.29 4.3 6.6 9.5 13.8 23.3 66 67.3 5000
RG – 58/U 53.5 4.95 10.2 14.8 22.3 32.8 55.8 66 93.5 1900
RG – 58A/U 50 4.95 10.8 16.1 23.9 37.7 70.5 66 101 1900
RG – 58C/U 50 4.95 10.8 16.1 23.9 37.7 70.5 66 101 1900
RG – 59/U 73 6.15 7.9 11.2 16.1 23.3 39.4 66 68.9 2300
RG – 59B/U 75 6.15 7.9 11.2 16.1 23 39.4 66 67.3 2300
RG – 62/U 93 6.04 6.2 8.9 12.5 17.7 28.5 84 44.3 700
RG – 62B/U 93 6.15 6.6 9.5 13.8 20 36.1 84 44.3 700
RG – 122/U 50 4.06 14.8 23 32.8 49.9 87 66 101 1900
RG – 141A/U 50 4.83 6.9 10.5 15.4 22.6 42.7 69.5 95.1 1900
RG – 142B/U 50 4.95 8.9 12.8 18.4 26.9 44.3 69.5 95.2 1900
RG – 174/U 50 2.56 21.7 29.2 39.4 57.4 98.4 66 101 1500
RG – 178B/U 50 1.83 34.4 45.9 62.3 91.9 150.9 69.5 95.1 1000
RG – 179B/U 75 2.54 27.9 32.8 41 52.5 78.7 69.5 64 1200
RG – 180B/U 95 3.56 15.1 18.7 24.9 35.1 55.8 69.51 49.2 1500
RG – 187A/U 75 2.66 27.9 32.8 41 52.5 78.7 69.5 64 1200
RG – 188A/U 50 2.59 31.5 37.4 46.6 54.8 101.7 69.5 95.2 1200
RG – 196A/U 50 1.93 34.4 45.9 62.3 91.9 150.9 69.5 95.2 1200
RG – 213/U 50 10.29 5.2 7.2 10.5 15.4 29.2 66 101 5000
RG – 214/U 50 10.8 5.2 7.2 10.5 15.4 29.2 66 101 5000
RG – 223/U 50 5.38 10.1 14.8 21 30.2 53.5 66 101 1900
RG – 303/U 50 4.31 6.9 10.5 15.4 22.6 42.7 69.5 95.2 1900
RG – 316/U 50 2.49 30.8 34.1 43.3 54.1 101.7 69.5 95.2 1200
BEL 9913 50 10.29 3 4.6 5.9 8.5 14.8 84 78.7
CNT-400 50 10.29 2.9 4.3 5.5 8 12.7 85
LM-400 50 10.29 2.8 3.9   9.1 13.8 85 77.1 2500

 

We’ve done some tests and concluded that RG11  is a good choice for its high dielectric breakdown characteristics and isn’t too heavy for the connector itself. RG11 is a 75 ohm cable but that isn’t significant for HV purposes, except that there tends to be a higher ratio of dielectric insulator to metal, than for 50 ohm cables, which means that their voltage breakdown should be higher. This combination should mean that the total assembly can be specified at the same voltage as the connectors themselves.